SF6 - MEASURING DEVICES :

3-026-R002 SF6 Warning device


The DILO SF6 warning device is used for the permanent control of ambient air for inadmissibly high SF6 concentrations and for the leak control of SF6 plants in closed rooms.


Response time:

 

approx. 1 min. with 2 m (6.6 ft) connecting hose
Contact output:

 

2 potential free alternating contacts 2.5 A 250 V AC
Operating temperature:
+ 0 to + 40°C

 

Alarm set:
to 2.0 vol.-% SF6/air
Measuring accuracy:
± 0.5 vol.-% SF6-share

SF6 warning device

3-026-R100 SF6-Network Monitor


Device for monitoring the air of indoor SF6 plants. Indication of the measured value via LEDs on the front of the device.


Possibility to connect the device to the SF6 -Network Controller via bus system.


Measuring range:
500 up to 2000 ppmv
Indication: 

 

 

via 4 LEDs on the front of the device for 500, 1000, 1500 or 2000 ppm
Operating voltage:
100 V - 240 V AC, 50/60 Hz, 18 VA
Humidity (during operatrion): 
10 to 90 % non condensing
System of protection:
IP 52

 

Operating temperature:
-5 to 45°C

NETWORK MONITOR

3-026-R110 SF6-Network Controller


Connection up to 12 SF6-Network monitors via an electrical bus system.


Indication:
touch screen 14.8 cm (5.8")v
Max. length of the bus system: 
1000 m

NETWORK Controller

3-027-R002 SF6 Volume percentage measuring device


Volume percentage measuring device with digital display, measuring cell with electronic part, 2 meter long connecting hose with coupling DN8 and DN20


Measuring media:
SF6/N2 of SF6/air-gas mixtures
Measuring range:
0 - 100 volume-% SF6
Measuring accuracy:
± 1 vol.-% for SF6/N2- or SF6/air-gas mixture
Operating pressure: 

 

Input pressure without pressure regulation pa = 1.7 to 10 bar
Operating temperature:
Temperature compensation of
- 20°C to + 40°C
Interface:
RS 232

NETWORK MONITOR

3-035-R20 SF6 Analyser 973


The SF6-Analyser 973 was designed for measurement of humidity and purity in SF6-gas insulated switchgear. Humidity measurement is displayed in ppmv, ppmw, dew/frost point at either system pressure or standard pressure. Purity measurement is displayed directly in SF6 volume percent.


Measuring range:

 

frost/dew point -50 °C ... +20 °C
Measuring accuracy:

 

 

 

 

 

frost/dew point ≤ ± 0.4 °C
ppmv/ppmw ± 5 % of measured value
SF6 volume percent ± 0.5 %
pressure ± 30 mbar

SF6 Analyser

3-032-R003 Measuring device for different decomposition products and gas residues


With this measuring device the following decomposition products can be measured:
- Sulphur dioxide SO2
- Hydrogen fluoride HF


Oil mists can additionally be detected. The concentrations of decomposition products and oil mist are indicated in ppm. The following concentrations can be measured:


Sulphur dioxide SO2
1 to 500 ppmv

 

Hydrogen fluoride HF:
1.5 to 15 ppmv

 

Oil mist:
1 to 10 mg/m³ (0.16 to 1.6 ppmm)

MEASURING DEVICE DECOMPOSITION

3-033-R002 Gas leak detector


Microprocessor control, with advanced digital signal processing Tricolor visual LED display and audible signal for progressive leak-size indication

 


Power supply: 

 

3 V = two 1.5 V "C"-cell alkaline batteries
Guaranteed sensitivity:
14 g SF / year (0.5 oz / year)
Operating temperature:
0°C to + 52°C

 

Battery life: 
approx. 30 hours
Method of operation:
continuous operation withour limitation
Response time:
immediately
Reset time:
1 second
Warm-up time:
approx. 2 seconds
Fixed sensor length:
355 mm

GAS LEAK DETECTOR SF6 Leak Check

3-032-R... Portable SO2 measuring device with LED display


The 3-032-R... measuring device has been designed to show a high resistance against contamination and SF6 decomposition products. For this reason the device does not only measure with more precision and reliability but even minimizes the usually long term drifting. Pressure and temperature influences on the measuring result can be excluded. The values are displayed in ppmv.


Available measuring ranges:

 

R101 = 0 - 20 ppmv
R102 = 0 - 100 ppmv
R103 = 0 - 500 ppmv

Portable SO2 Measuring Device

3-037-R001 Portable moisture measuring device


Moisture measuring device wiht digital display, mains-operated or by NiMH batteries (battery charger is integrated)


Indicating range: 
- 80 to + 20°C
Measuring range: 
- 50 to + 10°C dew point
Measuring accuracy:
± 4°C

 

Max. input pressure:
pe 10 bar

 

Operating temperature:
0 - 40°C

 

Operating voltage:
100 - 240 V / 50/60 HZ

PORTABLE MOISTURE MEASURING DEVICE

3-038-R... SF6 Multi-Analyser without recirculation system

3-038-R... SF6 Multi-Analyser with recirculation system


The SF6 Multi-Analyser is an important component in the reuse of SF6-gas to determine the gas quality used in medium and high voltage switchgear. The device with recirculation system can additionally be used for storing and reclaiming SF6 measuring gas.


The SF6 Multi-Analyser allows to determine the three most important parameters for reuse of SF6-gas with only one measurement:


- SF6 concentration (%)
- Moisture concentration
- SO2 concentration (ppmv)
- Option: HF concentration (ppmv)


SF6 Multi Analyser

B151R90 Discharge gas collection unit and recirculation


Installed in a transport case
For storage and reclaiming of SF6 measuring gas


The discharge gas collection unit can be connected to a measuring device by the hoses included in the scope of supply. The measuring gas is collected and stored in an internal vessel by means of a compressor. After having carried out measurements the stored measuring gas can be pumped back from the internal storage vessel in the gas compartment connected (max. pe 9 bar) The stored measuring gas can also be pumped manually if required (max pe 9 bar)


SF6-gas is not released into the atmosphere!

Discharge gas collection unit and recirculation

B151R20 Discharge gas collection unit


For reclaiming and storing of SF6 measuring gas


1 m³/h compressor, pe 50 bar, particle filer, gauges, connecting hose for collecting the used gas from the measuring devices


connecting couplings for:
- gas compartment
- measuring device input
- measuring device output
- external gas bottle


internal storage vessel


all couplings are self-closing, electric control with automatic process control two (230 V) sockets for measuring devices


Operating voltage: 100-127 V, 220-240 V AC, 50/60 Hz


GAS COLLECTION UNIT

Z340R10 Adapter for measuring devices


In a portable plastic case


- Hose connection DN8
- Adapter for measuring gas connection
- Transition piece DN20 for bottle pressure reducer
- Pressure reducer for SF6 reference gas bottle
- Manifold with self-closing couplings
- Manifold for measuring gas output
- 4 m long extension hose

Adapter for measuring devices
SF6 Leak Check

 

Site developed by W2WIN Technologies